← All industries
Industry 15

Security & surveillance

Power and data connections for cameras, access control and alarm equipment.

Cameras, door controllers, readers, alarm panels and recorders all need power and data — inside the housing, at the device pigtail, and between devices. For equipment makers and system integrators, the work is matching each device’s connector, the cable run and the mounting location. Outdoor sealing, PoE power and run length are confirmed per project, never assumed.

Illustrative application photo, not a customer project
Typical assemblies

What security equipment makers and integrators need

01

Camera pigtails

Multi-connector device tails — network, DC power, audio and alarm I/O — molded or sleeved, to your pinout and length.

02

Internal camera harnesses

Fine-pitch leads between sensor board, main board, IR and heater modules inside fixed and PTZ housings.

03

Access control cabling

Reader, lock, exit-button and door-contact leads with the connectors each device uses, labeled per door.

04

Alarm and sensor leads

Detector, siren and panel wiring in multi-conductor cable — conductor count, gauge and color code per your spec.

05

Power and PoE connections

DC power leads, splitters and network jumpers. PoE class, voltage drop and run length are checked against your device requirements.

06

Outdoor and sealed connections

Overmolded connectors, glands and sealed junctions where the installation needs them; the ingress rating is confirmed per project.

What matters here

What gets checked before the PO

Security devices are installed once and expected to stay connected. These details are confirmed before quoting.

Device interfacesConnector types and pinouts for each camera, reader, lock and panel — from the device drawing or a sample
PowerSupply voltage, current and PoE class per device, with run length checked for voltage drop
DataNetwork, serial or coax link type and length — the data rate you need is confirmed against the cable actually quoted
EnvironmentIndoor, outdoor or vandal-exposed mounting; UV, temperature and moisture decide the jacket and sealing. No ingress rating is assumed
Pigtail constructionOvermolded, sleeved or heat-shrunk breakouts; where molding is used, tooling cost and ownership are stated up front
ComplianceCable ratings such as plenum or riser, and RoHS/REACH materials, as you specify for the installation market
TestingContinuity and pull-force per the agreed plan